<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>j3w5.de – Daikin (Rotex)</title><link>https://j3w5.de/kb/daikin/</link><description>Recent content in Daikin (Rotex) on j3w5.de</description><generator>Hugo -- gohugo.io</generator><language>en</language><atom:link href="https://j3w5.de/kb/daikin/index.xml" rel="self" type="application/rss+xml"/><item><title>Kb: RTX-AL4 Board</title><link>https://j3w5.de/kb/daikin/rtx-al4-5011537/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://j3w5.de/kb/daikin/rtx-al4-5011537/</guid><description>
&lt;p>Very often, when a Rotex/Daikin HPSU fails with error codes E200 or E8100, the two 100uF capacitors on the little driver board are to blame.&lt;/p>
&lt;p>The fact that those are rated 85°C only, and sit close to heated parts inside the HPSU, are not really helpful for their lifespan.&lt;/p>
&lt;div class="pageinfo pageinfo-primary">
&lt;p>These instructions are provided “AS IS” and without any warranty of any kind.&lt;/p>
&lt;/div>
&lt;h3 id="the-board">The board&lt;/h3>
&lt;p>RTX-AL4 Board with original (defective) capacitors. (front &amp;amp; back)&lt;/p>
&lt;div class="gallery">
&lt;a href="https://j3w5.de/kb/daikin/rtx-al4-5011537/board/IMG_20230514_203802.jpg" class="gallery-item glightbox" data-gallery="my-gallery">
&lt;img src="https://j3w5.de/kb/daikin/rtx-al4-5011537/board/IMG_20230514_203802.jpg" alt="board/IMG_20230514_203802.jpg" class="img-fluid rounded mb-2" />
&lt;/a>
&lt;a href="https://j3w5.de/kb/daikin/rtx-al4-5011537/board/IMG_20230514_203809.jpg" class="gallery-item glightbox" data-gallery="my-gallery">
&lt;img src="https://j3w5.de/kb/daikin/rtx-al4-5011537/board/IMG_20230514_203809.jpg" alt="board/IMG_20230514_203809.jpg" class="img-fluid rounded mb-2" />
&lt;/a>
&lt;/div>
&lt;style>
.gallery {
column-count: 3;
column-gap: 15px;
}
.gallery-item {
display: inline-block;
width: 100%;
margin-bottom: 15px;
break-inside: avoid;
}
.gallery img {
width: 100%;
height: auto;
border-radius: 4px;
transition: transform 0.2s ease;
}
.gallery img:hover {
transform: scale(1.05);
}
@media (max-width: 992px) {
.gallery {
column-count: 2;
}
}
@media (max-width: 576px) {
.gallery {
column-count: 1;
}
}
&lt;/style>
&lt;h3 id="test-the-components">Test the components&lt;/h3>
&lt;p>The defective capacitors, made by NOVER: 100µF, 63V, 85°C&lt;/p>
&lt;div class="gallery">
&lt;a href="https://j3w5.de/kb/daikin/rtx-al4-5011537/badcaps/IMG_20230514_203835.jpg" class="gallery-item glightbox" data-gallery="my-gallery">
&lt;img src="https://j3w5.de/kb/daikin/rtx-al4-5011537/badcaps/IMG_20230514_203835.jpg" alt="badcaps/IMG_20230514_203835.jpg" class="img-fluid rounded mb-2" />
&lt;/a>
&lt;a href="https://j3w5.de/kb/daikin/rtx-al4-5011537/badcaps/IMG_20230514_203911.jpg" class="gallery-item glightbox" data-gallery="my-gallery">
&lt;img src="https://j3w5.de/kb/daikin/rtx-al4-5011537/badcaps/IMG_20230514_203911.jpg" alt="badcaps/IMG_20230514_203911.jpg" class="img-fluid rounded mb-2" />
&lt;/a>
&lt;/div>
&lt;style>
.gallery {
column-count: 3;
column-gap: 15px;
}
.gallery-item {
display: inline-block;
width: 100%;
margin-bottom: 15px;
break-inside: avoid;
}
.gallery img {
width: 100%;
height: auto;
border-radius: 4px;
transition: transform 0.2s ease;
}
.gallery img:hover {
transform: scale(1.05);
}
@media (max-width: 992px) {
.gallery {
column-count: 2;
}
}
@media (max-width: 576px) {
.gallery {
column-count: 1;
}
}
&lt;/style>
&lt;p>Both are expected to have a capacity of 100µF each, but only 4µF remain. This is insufficient to provide the power required.&lt;/p>
&lt;div class="gallery">
&lt;a href="https://j3w5.de/kb/daikin/rtx-al4-5011537/meterbad/IMG_20230514_204031.jpg" class="gallery-item glightbox" data-gallery="my-gallery">
&lt;img src="https://j3w5.de/kb/daikin/rtx-al4-5011537/meterbad/IMG_20230514_204031.jpg" alt="meterbad/IMG_20230514_204031.jpg" class="img-fluid rounded mb-2" />
&lt;/a>
&lt;a href="https://j3w5.de/kb/daikin/rtx-al4-5011537/meterbad/IMG_20230514_204047.jpg" class="gallery-item glightbox" data-gallery="my-gallery">
&lt;img src="https://j3w5.de/kb/daikin/rtx-al4-5011537/meterbad/IMG_20230514_204047.jpg" alt="meterbad/IMG_20230514_204047.jpg" class="img-fluid rounded mb-2" />
&lt;/a>
&lt;/div>
&lt;style>
.gallery {
column-count: 3;
column-gap: 15px;
}
.gallery-item {
display: inline-block;
width: 100%;
margin-bottom: 15px;
break-inside: avoid;
}
.gallery img {
width: 100%;
height: auto;
border-radius: 4px;
transition: transform 0.2s ease;
}
.gallery img:hover {
transform: scale(1.05);
}
@media (max-width: 992px) {
.gallery {
column-count: 2;
}
}
@media (max-width: 576px) {
.gallery {
column-count: 1;
}
}
&lt;/style>
&lt;h3 id="replacements-for-capacitors">Replacements for capacitors&lt;/h3>
&lt;p>I prefer capacitors from Nichicon or Panasonic, both are rated for 105°C instead of 85°C.&lt;/p>
&lt;ul>
&lt;li>NICHICON Elko UPW1J101MPD: Low ESR 0,256R 100uF 63V 10x12,5mm RM5&lt;/li>
&lt;li>Panasonic Elko EEUFR1J101: FR 100uF 63V Kondensator 105°C Low ESR&lt;/li>
&lt;/ul>
&lt;h3 id="replace-the-100µf-capacitors">Replace the 100µF capacitors&lt;/h3>
&lt;div class="gallery">
&lt;a href="https://j3w5.de/kb/daikin/rtx-al4-5011537/replace/IMG_20230514_204705.jpg" class="gallery-item glightbox" data-gallery="my-gallery">
&lt;img src="https://j3w5.de/kb/daikin/rtx-al4-5011537/replace/IMG_20230514_204705.jpg" alt="replace/IMG_20230514_204705.jpg" class="img-fluid rounded mb-2" />
&lt;/a>
&lt;a href="https://j3w5.de/kb/daikin/rtx-al4-5011537/replace/IMG_20230514_204720.jpg" class="gallery-item glightbox" data-gallery="my-gallery">
&lt;img src="https://j3w5.de/kb/daikin/rtx-al4-5011537/replace/IMG_20230514_204720.jpg" alt="replace/IMG_20230514_204720.jpg" class="img-fluid rounded mb-2" />
&lt;/a>
&lt;a href="https://j3w5.de/kb/daikin/rtx-al4-5011537/replace/IMG_20230514_205140.jpg" class="gallery-item glightbox" data-gallery="my-gallery">
&lt;img src="https://j3w5.de/kb/daikin/rtx-al4-5011537/replace/IMG_20230514_205140.jpg" alt="replace/IMG_20230514_205140.jpg" class="img-fluid rounded mb-2" />
&lt;/a>
&lt;/div>
&lt;style>
.gallery {
column-count: 3;
column-gap: 15px;
}
.gallery-item {
display: inline-block;
width: 100%;
margin-bottom: 15px;
break-inside: avoid;
}
.gallery img {
width: 100%;
height: auto;
border-radius: 4px;
transition: transform 0.2s ease;
}
.gallery img:hover {
transform: scale(1.05);
}
@media (max-width: 992px) {
.gallery {
column-count: 2;
}
}
@media (max-width: 576px) {
.gallery {
column-count: 1;
}
}
&lt;/style>
&lt;h3 id="verify-that-the-new-capacitors-work-correctly">Verify that the new capacitors work correctly&lt;/h3>
&lt;p>Before installing the board back into its place, make sure that the caps did not get damaged by soldering.&lt;/p>
&lt;div class="gallery">
&lt;a href="https://j3w5.de/kb/daikin/rtx-al4-5011537/metergood/IMG_20230514_205259.jpg" class="gallery-item glightbox" data-gallery="my-gallery">
&lt;img src="https://j3w5.de/kb/daikin/rtx-al4-5011537/metergood/IMG_20230514_205259.jpg" alt="metergood/IMG_20230514_205259.jpg" class="img-fluid rounded mb-2" />
&lt;/a>
&lt;a href="https://j3w5.de/kb/daikin/rtx-al4-5011537/metergood/IMG_20230514_205310.jpg" class="gallery-item glightbox" data-gallery="my-gallery">
&lt;img src="https://j3w5.de/kb/daikin/rtx-al4-5011537/metergood/IMG_20230514_205310.jpg" alt="metergood/IMG_20230514_205310.jpg" class="img-fluid rounded mb-2" />
&lt;/a>
&lt;/div>
&lt;style>
.gallery {
column-count: 3;
column-gap: 15px;
}
.gallery-item {
display: inline-block;
width: 100%;
margin-bottom: 15px;
break-inside: avoid;
}
.gallery img {
width: 100%;
height: auto;
border-radius: 4px;
transition: transform 0.2s ease;
}
.gallery img:hover {
transform: scale(1.05);
}
@media (max-width: 992px) {
.gallery {
column-count: 2;
}
}
@media (max-width: 576px) {
.gallery {
column-count: 1;
}
}
&lt;/style></description></item></channel></rss>